BZZCR - TEFLON ENAMEL-CLEAR, 852-201

Product Identification

Product ID:TEFLON ENAMEL-CLEAR, 852-201
MSDS Date:06/14/1993
FSC:8010
NIIN:00N000220
MSDS Number: BZZCR

Responsible Party
E I DUPONT DE NEMOURS & CO
1007 MARKET ST
WILMINGTON, DE 19898
US

Emergency Phone: 800-441-3637;800-424-9300(CHEMTREC)

Info Phone: 800-441-7515

Cage: 0ERJ7

Contractor
E.I. DUPONT DE NEMOURS & CO
WILMINGTON, DE 19898 US

Telephone: 800-441-7515;800-441-9442

Cage: 18873

Ingredients

NONIONIC SURFACTANT

CAS: 68145-97-2

OSHA PEL N/K

ACGIH TLV: N/K


GLYCOLS, POLYETHYLENE, MONO ((1,1,3,3-

CAS: 9036-19-5

RTECS: MD0907600

OSHA PEL N/K

ACGIH TLV: N/K


TOLUENE (SARA 313) (CERCLA)

CAS: 108-88-3

RTECS: XS5250000

Fraction By Weight: 10-20%

OSHA PEL 200 PPM; Z-2

ACGIH TLV: 50 PPM

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


WATER

CAS: 7732-18-5

RTECS: ZC0110000

OSHA PEL N/K

ACGIH TLV: N/K


THEORETICAL 2.2.

RTECS: 9999999VO


ANIMALS & OCCAS PALPITATIONS IN HUMANS. RATS

RTECS: 9999999ZZ


FREQUENCY HEARING DEFICITS. THE SIGNIFICANCE OF THIS

RTECS: 9999999ZZ


LISTING OF OCCUPATIONAL CHEMICAL REPRODUCTIVE

RTECS: 9999999ZZ


CONCERNING LATEST HAZARD LIST INFORMATION AND SAFE

RTECS: 9999999ZZ


BE EVOLVED; AMTS INCREASE AS TEMPS INCREASE.

RTECS: 9999999ZZ


(3PPM - CEILING ACGIH-TLV). HIGH CONCS CAN CAUSE

RTECS: 9999999ZZ


PARTICULARLY SENSITIVE TO DMG BY HYDROGEN FLUORIDE

RTECS: 9999999ZZ


OCCUR >800F W/FINELY DIVIDED FLUOROCARBON & METAL

RTECS: 9999999ZZ


BUFFING/GRIT BLASTING MAY GENERATE SUCH MIXTURES.

RTECS: 9999999ZZ


ETHYLENE, TETRAFLUORO-, POLYMER; (POLYTETRAFLUOROETHYLENE)

CAS: 116-14-3

RTECS: KX4025000

OSHA PEL N/K

ACGIH TLV: N/K

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHAL:MAY CAUSE NOSE & THROAT IRRIT.
MAY CAUSE NERV SYS DEPRESS CHARACT BY FOLLOWING PROGRESSIVE STEPS:
HDCH, DIZZ, NAUS, STAGGERING GAIT, CONFUSION, UNCON. SKIN/EYE: MAY
CAUSE IRRIT/BURNING OF EYES. RPTD/PRLNGD LIQ CONT MAY CAUSE SKIN
IRRIT W/DISCOMFORT & DERM. REPORTS HAVE ASSOC RPTD & PRLNGD
OVEREXP(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ:TO SOLVENTS W/PERM BRAIN & NERV SYS
DMG. ING 1:INHAL OF SMOKE/FUMES FROM BURNING
FLUOROCARBON/FLUOROCARBON CONTAMD CIGARETTES/TOBACCO MAY CAUSE
POLYMER FUME FEVER, FLU-LIKE ILLNESS W/FEVER, C HILLS & COUGH OF
APPROX 24-48 HRS DURATION, WHICH SUBSIDES W/OUT LASTING EFTS. ING
2: CONT MAY CAUSE SKIN IRRIT(SUPDAT)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:INHAL: REMOVE TO FRESH AIR. IF NOT BRTHG, GIVE ARTF RESP,
PREFERABLY MOUTH-TO-MOUTH. IF BRTHG DFCLTY PERSISTS/OCCURS LATER,
CONSULT MD. EYE: IMMED FLUSH W/PLENTY OF WATER FOR AT LEAST 15
MINS. CALL MD . SKIN:WASH W/SOAP & WATER. IF IRRIT OCCURS, CONTACT
MD. INGEST: GI DISTRESS, IN THE UNLIKELY EVENT OF INGESTION, CALL
MD IMMED & HAVE NAMES OF INGS AVAILABLE.

Fire Fighting

Flash Point Method:CC
Flash Point:>20F,>-7C
Lower Limits:1.3%
Upper Limits:7.0%
Extinguishing Media:FOAM, CARBON DIOXIDE, DRY CHEMICAL.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL
PROTECTIVE EQUIPMENT. WATER FROM FOG NOZZLES MAY BE USED TO PREVENT
PRESSURE BUILD-UP.
Unusual Fire/Explosion Hazard:WHEN HEATED >FLASHPOINT, EMITS FLAMMABLE
VAPORS WHICH, WHEN MIXED W/AIR, CAN BURN OR BE EXPLOSIVE. FINE
MIST/SPRAYS MAY BE FLAMMABLE AT TEMPS BELOW FLASHPOINT.

Accidental Release

Spill Release Procedures:VENT AREA. REMOVE SOURCES OF IGNIT. PVNT SKIN
CONTACT & BRTHG OF VAPOR. CONFINE & REMOVE W/INERT ABSORBENT.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:OBSERVE LABEL PRECS. KEEP AWAY FROM
HEAT, SPARKS & FLAME. CLOSE CNTNR AFTER EACH USE. GROUND CNTNRS
WHEN POURING. DO NOT STORE ABOVE 120F.
Other Precautions:DO NOT SAND, FLAME CUT, BRAZE/WELD DRY COATING W/OUT
A NIOSH/MSHA APPROVED RESPIRATOR/APPROP VENTILATION. DO NOT EXCEED
RECOM BAKING TEMPS. BAKING OVENS MUST BE PROPERLY VENT. AT TEMPS
>400C(750F) SMA LL AMTS OF HYDROGEN FLUORIDE CAN(ING 11)

Exposure Controls

Respiratory Protection:DO NOT BREATHE VAPORS/MISTS. WEAR PROPERLY
FITTED VAPOR/PARTICULATE RESP APPROVED BY NIOSH/MSHA (TC-23C) FOR
USE W/PAINTS DURING APPLIC & UNTIL ALL VAPS & SPRAY MISTS ARE
EXHAUSTED. FOLLOW RESP MFR'S DIRECTIONS FOR RESP USE.
Ventilation:PROVIDE SUFF VENT IN VOL & PATTERN TO KEEP CONTAMS OSHA REQS & OTHER SUGGESTED EXPOSURE LIMITS.
Protective Gloves:NEOPRENE GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGS(SUPDAT).
Other Protective Equipment:EMER EYEWASH & DELUGE SHOWER MEETING ANSI
DESIGN CRITERIA. DO NOT USE FOR PROT. MAY BE USED FOR EASE OF
CLEAN-UP.
Work Hygienic Practices:WASH THORO AFTER HANDLING & BEFORE
EATING/SMOKING.
Supplemental Safety and Health
EYE PROT: & FULL LENGTH FACESHIELD. EFTS OF OVEREXP: W/DISCOMFORT/RASH.
CAUSES EYE CORR & PERM INJURY. ING 3: CAUSES EYE CORR & PERM
INJURY. CONT MAY CAUSE SKIN IRRIT W/DISCOMFORT & RASH. ING 4:
RECURRENT OVEREXP MAY RSLT IN LIVER & KIDNEY INJURY. HIGH AIRBORNE
LEVELS HAVE PRDCED IRREG HEART BEATS IN (ING 7)

Chemical Properties

Boiling Pt:B.P. Text:>212F,>100C
Vapor Density:HVR/AIR
Spec Gravity:1.34
Evaporation Rate & Reference:SLOWER THAN ETHER
Solubility in Water:APPRECIABLE
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:65.9

Stability

Stability Indicator/Materials to Avoid:YES
NONE REASONABLY FORESEEABLE.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:CO, CO*2, SMOKE, OXIDES OF HEAVY
METALS REPORTED.

Disposal

Waste Disposal Methods:DO NOT ALLOW MATL TO CONTAMINATE GROUND WATER
SYSTEMS. INCINERATE ABSORBED MATL IN ACCORDANCE W/FEDERAL, STATE &
LOCAL REQUIREMENTS. DO NOT INCINERATE IN CLOSED CONTAINERS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.